EasyManua.ls Logo

Siemens SITRANS F US - 1.6 Technical data - transmitter SITRANS FUS060

Siemens SITRANS F US
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SFIDK.PS.029.E5.02 / SW 2.01.076
Output
Analog output
Signal range 4...20 mA active current output. (13.2V<open loop voltage<15.8V)
Upper limit 20...22.5 mA, adjustable
Signal on alarm 3.6 mA, 22 mA or 24 mA
Load Max 600 ohm for non Ex version
Max 330 ohm Ex version.
Only PROFIBUS PA version Analog output omitted, is replaced by digital PROFIBUS PA
interface
Digital output 1
Active or passive signal, can be configured Active: 24 V DC, 24 mA, R
i
= 300
with positive or negative logic
Passive: open collector, 30 V DC, 200 mA
For explosion protection
Passive: open collector, 30 V DC, 100 mA
ATEX II 2G Ex dem [ia/ib] T6..T3
Output function, configurable Pulse output
Adjustable pulse significance 5000 pulses/s
Adjustable pulse width 0.1 ms
Frequency output
f
END
selectable up to 10 kHz
Error in measurement:
(at reference conditions)
Pulse output ± 0.5% of measured value at 0.5 m/s to 10 m/s or
± 0.25 / v [m/s]% of measured value at flow < 0.5 m/s
Analog output As pulse output plus ± 0.1% ± 20 µA
Repeatability ± 0.25% of measured value at 0.5 m/s to 10 m/s
Digital output 2 (Relay)
Relay, NC or NO contact Switching capacity max. 5 W
Max. 50 V DC, max. DC 200 mA
Self-resetting fuse, R
i
= 9
For explosion protection Max. 30 V DC, for DC max. 100 mA, for AC max. 50 mA
ATEX II 2G Ex dem [ia/ib] IIC T6..T3 (cf. EC-Type Examination certificate)
Output function, configurable for: Alarm, flow direction, flow limits, sound velocity limits,
ultrasonic-amplitude limits, no function
Communication via analog output 4...20 mA
PC/laptop (PDM) or HART communicator
with SITRANS F flowmeter
Load Min. load 230 Ohm
Cable 2-wire shield 3 km ( 1.86 miles)
Multi-core shield 1.5 km ( 0.93 miles)
Protocol HART, version 5.1
Electrical isolation Outputs electrically isolated from power supply and
from each other (Output isolation 63 Vac/100 Vdc to ground.)
Ambient temperature (transmitter) -20...+50 °C (-4...+122 °F)
In potentially explosive atmospheres Observe temperature class
Storage temperature -25...+80 °C (-13...+176 °F)
Enclosure rating IP65
Electromagnetic compatibility For use in industrial environments
Emission EN 61000-6-3 (Light industry)
Immunity EN 61000-6-2 (Industry)
Use shield cables for the outputs
1.6 Technical data - transmitter SITRANS FUS060

Table of Contents

Other manuals for Siemens SITRANS F US

Related product manuals