SFIDK.PS.029.E5.02 / SW 2.01.0738
Digital output 1 menu 4.2
Function menu 4.2.1
The digital output 1 (implemented for both HART and PA interfaces) can indicate flow (impulse
or frequency) and some alarms/limits.
Analog Input Function
Block 1 - Flow
Volume flow [m
3
/s]
Volume /Imp ulse
Volume [m
3
]
Volume/Frequency
Digital Output 1
Alarm
Flow dir.forward
Flow min
Flow max
Flow min/max
Total. forw. max
Total. rev. min
Total. net min
Total. net max
No action
Diagnostics
phys_dout1_select
Signal type, menu 4.2.2
Different signal types can be configured for the output signal of digital output 1.
- Active: Device-internal voltage used (+24 V).
- Passive: External supply necessary.
In the device version with protection type ATEX II 2G Ex dem [ia/ib] IIC T6..T3 with intrinsically
safe output only passive:
HART: Active or passive. PROFIBUS: Only passive.
Active
Passive
Active and passive signals