5.6 SITRANS LVS200 Pipe extension version
SITRANS LVS100/200
Operating Instructions, 01/2019, A5E44839609-AA
31
5.6.2
Extension tube dimensions
Version with G1" (DIN ISO 228-1) thread
Pipe length x
LVS200 (7ML5733 with short fork, application type 2, liquids/solids interface): X = L - 180 mm (X
= L - 7.1")
LVS200 (7ML5733 with standard fork, application type 1): X = L - 250 mm (X = L - 9.8")
LVS200 (7ML5733 with standard fork, application type 1 and z option K05 or G01, enhanced
sensitivity): X = L - 275 mm (X = L - 10.8")
Note: L is the total extension length
Effective thread length
Same as other end
Free from burrs