SITRANS LVS100/200
Operating Instructions, 01/2019, A5E44839609-AA
45
Note
The clamping screws of the sliding bushing must be tightened to 10 Nm.
8.4
Zone classification
Universal voltage Relay SPDT
Universal Voltage Relay DPDT
3-wire PNP
2 wire without contact
8/16 mA or 4-20 mA (Non-intrinsically
safe)
NAMUR IEC 60945-5-6 (Intrinsically
Safe)
8/16 mA or 4-20 mA (Intrinsically Safe)
**A
EPL (IECEx)
Da
Db
Da
Db
Ga
Gb
Category
(ATEX)
1D 2D 1D 2D 1G 2G
Zone
20
21
20
21
0
1
**B
EPL (IECEx)
Da
Da
Da
Da
Ga
Ga
Category
(ATEX)
1D 1D 1D 1D 1G 1G
Zone
20
20
20
20
0
0