SITRANS LVS100/200
Operating Instructions, 01/2019, A5E44839609-AA
39
LVS100 version with 2 relays DPDT relay fail-safe: high or low,
switch selectable
relay 8 A at 250 V AC, non-
inductive / relay 5 A at 30 V DC,
LVS200 version with 1 relay SPDT relay fail-safe: high or low,
switch selectable
relay 8 A at 250 V AC, non-
inductive / relay 5 A at 30 V DC,
version with 2 relays DPDT relay fail-safe: high or low,
switch selectable
relay 8 A at 250 V AC, non-
inductive / relay 5 A at 30 V DC,
3-wire PNP open collector: permanent load
maximum 0.4 A, short circuit and
overload protected; turn-on voltage:
max. 50 V (reverse protection)
mA output (build-up
8/16 mA or 4 to 20 mA; resolution 4
LVS100 thread R 1½" (BSPT); 1¼" NPT (Taper)
ANSI B 1.20.1
thread material stainless steel 316 Ti (1.4581) or
304 (1.4301) for specific configura-
LVS200
1½” NPT (Taper), R 1½” (BSPT)
thread material stainless steel 304 (1.4301) or op-
tional stainless steel 316 Ti
flanges DN 100 PN6, DN 100 PN16, 2", 3",
optional sliding bushing with R 2" (BSPT) or NPT (Taper)
Tines tine material
(PTFE
1
coated tines
are available upon
special request. Con-
tact your local Siemens
representative for or-
stainless steel 316Ti (1.4571)/ 316L
(1.4581)
Enclosure
conduit entry 2 x M20x1.5, or 2 x ½” NPT
Weight standard version, no
2.0 kg (4.4 lb)
solids/liquids, no ex-
1.9 kg (4.2 lb)