EasyManua.ls Logo

Siemens ST750 - Figure 28 - Allocation of Red Lamp Monitor Channels for ST750 LED Controllers with LV CLS (NLM) Monitoring

Siemens ST750
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ST750 GENERAL HANDBOOK
667/HB/33750/000 Page 77 Issue 6
A
G
R
PL6
LMU + RLM
LMU + RLM
RAU
RA1
YA1
GA1
RA2
YA2
GA2
5
6
G
W
LMU only
RB (Red Man)
GB (Green Man)
YB Wait
LMU only
Phase A
Phase B
Vehicle
Supply
230V
Triacs
and
Monitors
Pedestrian
Supply
230/48V
Wait
Supply
48V
34
R
Triacs
and
Monitors
Vehicle RLM
Channel 1
Vehicle RLM
Channel 2
38
A
G
R
PL7
LMU + RLM
LMU + RLM
RAU
RA1
YA1
GA1
RA2
YA2
GA2
7
8
G
W
LMU only
RB (Red Man)
GB (Green Man)
YB Wait
LMU only
Phase C
Phase D
Vehicle
Supply
230V
Triacs
and
Monitors
Pedestrian
Supply
230/48V
Wait
Supply
48V
36
R
Triacs
and
Monitors
Vehicle RLM
Channel 1
Vehicle RLM
Channel 2
40
RLM
PL8
RLM
33
37
RA3 Vehicle RLM Channel 3
RA4 Vehicle RLM Channel 4
No external RLM on Phase C
Figure 28 - Allocation of Red Lamp Monitor Channels for ST750LED
Controllers with LV CLS (NLM) monitoring

Table of Contents

Other manuals for Siemens ST750

Related product manuals