EasyManua.ls Logo

Sierra Wireless GL6110 - Corrosive Resistance Stress Test; Thermal Resistance Cycle Stress Test; Table 56: Environmental Resistance Stress Test; Table 57: Corrosive Resistance Stress Test

Sierra Wireless GL6110
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WA_DEV_GL6100_PTS_001 Rev 002 May 24, 2010 72
GL61x0 Product Technical
Specification and User Guide
Reliability Standards: Compliance and
Recommendations
Table 56: Environmental Resistance Stress Test
Designation
Condition
Cold Test
COT
Standard: IEC 680068-2-1, Test Ab
Special conditions:
Temperature: -40°C
Rate of temperature change: dT/dt >= ± 3°C/min
Recovery time: 3 hours
Operating conditions: Un-powered
Duration: 72 hours
13.4.3. Corrosive Resistance Stress Test
The following tests the GL61x0s resistance to corrosive atmosphere.
Table 57: Corrosive Resistance Stress Test
Designation
Condition
Moist Heat Cyclic Test
MHCT
Standard: IEC 60068-2-30, Test Db
Special conditions:
Upper temperature: +55 ± 2°C
Lower temperature: +25 ± 2°C
RH:
Upper temperature: 93%
Lower temperature: 95%
Number of cycles: 21 (1 cycle/24 hours)
Rate of temperature change: dT/dt >= ± 3°C/min
Recovery time: 3 hours
Operating conditions: Un-powered
Duration: 21 days
13.4.4. Thermal Resistance Cycle Stress Test
The following tests the GL61x0s resistance to extreme temperature cycling.
Table 58: Thermal Resistance Cycle Stress Test
Designation
Condition
Thermal Shock Test
Standard: IEC 60068-2-14

Table of Contents

Related product manuals