Parameter description
AP04-RS485/SIKONETZ5
Date: 24.11.2016 Art. No. 86218 Mod. status 351/16 Page 19 of 38
Positioning window2:
Additional target window for
detecting an approach to target
window1 (see also Parameter no.
29 and chapter 3.2 Position
monitoring seq.).
Visualization
of target
window2
Visualization of the "target
window2 reached" state
Selection:
0 = Off
1 = LED1 glows green
2 = LED1 glows red
If the actual position is inside
target window2, but outside target
window1, the LED display glows as
set here. Additionally, blinking of
the LED is inverted to Parameter
no. 14: LED blinking switched on.
Type of positioning:
0 = direct: direct travelling from
actual position to set point
possible.
1 = loop +: travelling to the set
point must always be in positive
direction to compensate for
spindle play.
2 = loop -: travelling to the set
point must always be in negative
direction to compensate for
spindle play.
Loop length:
see chapter 3.3 Loop positioning
Differential
value
calculation
Calculation of the differential
value:
0 Differential value = actual
position - set point
1: Differential value = actual
position - actual position
System Status Word
see chapters 7.3 System Status
Word and 8.3.5 Status word
Battery voltage:
Values in 1/100 V