CM5_UM_ 9752090319_GB_V0_9 37 / 67
1000 Menu option that shows the generator's current operating mode. By selecting the option,
the operating mode of the generator can be changed.
2000 Menu option that shows the generator's current 'Control' mode. By selecting the option,
the 'Control' mode of the generator can be changed.
3000 Menu for changing the settings for the ‘Local’ operating mode.
3100 VC: set value for the Voltage Setpoint when the generator is operating in Local
mode.
CC: set value for the Current Setpoint when the generator is operating in Local
mode.
3110 VC: set the Voltage Setpoint.
CC: set the Current Setpoint.
3200 VC: set the Current Limit when the generator is operating in Local mode.
CC: set the Voltage Limit when the generator is operating in Local mode.
3210 VC: set the Current Limit.
CC: set the Voltage Limit.
4000 Menu for changing the settings for the ‘Remote’ operating mode.
4100 VC: set value of the Voltage Setpoint when the generator is operating in Remote
mode.
CC: set value of the Current Setpoint when the generator is operating in
Remote mode.
4200 VC: set value of the Current Limit when the generator is operating in Remote
mode.
CC: set value of the Voltage Limit when the generator is operating in Remote
mode. When option 4320 is enabled, the set value can only be read out. When
option 4310 is enabled, option 4210 is also enabled, meaning that the set value
can be changed.
4210 VC: set the Current Limit.
CC: set the Voltage Limit.
4300 Configure the maximum current (VC mode) or maximum voltage (CC mode)
setting in Remote operating mode.
4310 The maximum current/voltage is set locally via the menu (see 4210).
4320 The maximum current/voltage is controlled via the remote I/O.
5000 Menu for changing the settings for the ‘Fieldbus’ operating mode.
5100 VC: set value of the Voltage Setpoint when the generator is operating in
Fieldbus mode.
CC: set value of the Current Setpoint when the generator is operating in
Fieldbus mode.
5200 VC: set value of the Current Limit when the generator is operating in Fieldbus
mode.
CC: set value of the Voltage Limit when the generator is operating in Fieldbus
mode.
6000 Menu for changing the settings for the ‘Advanced Output Control’ operating mode.