Appendix IV Operating signal
Power Operating
mode
Remote
HV on/off
mode
Local
setpoint
Fieldbus
setpoint
Remote
setpoint
External
remote
HV on/off
Run
button
Limited
error
Operating
Off
* * * * * * * * 0
On Local
setpoint
Disabled 0 kV * * * * * 0
On Local
setpoint
Disabled 1 kV * * * * 0 1
On Local
setpoint
Disabled 1 kV * * * * 1 0
On Local
setpoint
Enabled 0 kV * * * * * 0
On Local
setpoint
Enabled 1 kV * * 0 0 * 0
On Local
setpoint
Enabled 1 kV * * 0 1 0 1
On Local
setpoint
Enabled 1 kV * * 0 1 1 0
On Local
setpoint
Enabled 1 kV * * 1 * 0 1
On Local
setpoint
Enabled 1 kV * * 1 * 1 0
On Fieldbus
setpoint
Disabled * 0 kV * * * * 0
On Fieldbus
setpoint
Disabled * 1 kV * * * 0 1
On Fieldbus
setpoint
Disabled * 1 kV * * * 1 0
On Fieldbus
setpoint
Enabled * 0 kV * * * * 0
On Fieldbus
setpoint
Enabled * 1 kV * 0 0 * 0
On Fieldbus
setpoint
Enabled * 1 kV * 0 1 0 1
On Fieldbus
setpoint
Enabled * 1 kV * 0 1 1 0
On Fieldbus
setpoint
Enabled * 1 kV * 1 * 0 1
On Fieldbus
setpoint
Enabled * 1 kV * 1 * 1 0
On Remote
setpoint
Disabled * 0 kV * * * 0
On Remote
setpoint
Disabled * 1 kV * * 0 1
On Remote
setpoint
Disabled * 1 kV * * 1 0
On Remote
setpoint
Enabled * 0 kV * * * 0
On Remote
setpoint
Enabled * 1 kV 0 0 * 0
On Remote
setpoint
Enabled * 1 kV 0 1 0 1
On Remote
setpoint
Enabled * 1 kV 0 1 1 0
On Remote
setpoint
Enabled * 1 kV 1 * 0 1
On Remote
setpoint
Enabled * 1 kV 1 * 1 0
* = Don’t care.