CM5_UM_ 9752090319_GB_V0_9 9 / 67
4 Technical specifications
Required power supply:
Supply voltage 100–240 V AC
Supply voltage limit values 85–264 V AC
Frequency 50–60 Hz
Frequency limit values 47–63 Hz
Current power Max. 240 W
Connection Euro connector IEC-320
Fuse (rear): 3.15 AT
Output:
CM5 30N (30P) CM5 60N (60P)
Max. output voltage 30 kV DC 60 kV DC
Max. output current 5 mA 2.5 mA
Max. output power 150 W 150 W
High voltage connection 4x spring connector 4x spring connector
Voltage stabilisation 2% of max. output voltage
Load stabilisation 2% of max. output voltage
Output voltage Can be set between 0 kV and max. output voltage
Ripple, peak-peak 5% of max. output voltage at maximum load
User interface:
Operation
4x cursor keys, ESC key and key
Limit indicator Red LED
Display 4x 20 character LCD with background lighting
Accuracy 5% of the maximum voltage ± 2 digits
Digital I/O:
Bus module 1x Anybus connector. The Anybus module is optional.
For the available networks and protocols, contact
SIMCO (Nederland) B.V. or your local representative
Additional options - Switching the high voltage on/off
- Readout of the output voltage (absolute and
percentage values)
- Readout of the output current (absolute and
percentage values)
- Setting the output voltage or current (absolute and
percentage values)
- Setting the maximum output current or voltage
I/O analogue (via the 25-pin sub-D
connector):
External bus supply voltage input Specification:
10 V DC, 0.5 A max / 27 V DC, 0.2 A max.
Remote HV on/off input 0 V = off, 10-30 V = on (typically 12 V)
Specification:
10 V DC, 10 mA min / 30 V DC, 25 mA max.
Status indicators (Operation and Limit
Alarm/Arc Detect)
30 V DC, 10 mA max.
Analogue control voltage Specification:
0–5 V DC or