EasyManua.ls Logo

Simco CM5 - Appendix V Connector Connections

Simco CM5
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CM5_UM_ 9752090319_GB_V0_9 58 / 67
Appendix V Connector connections
Connector connections for the 25-pin sub-D connector at the rear of the generator:
Pin 1 = External remote HV on/off + (plus)
Pin 2 = Remote I setpoint
Pin 3 = Remote U setpoint
Pin 4 = Remote U output
Pin 5 = Remote I output
Pin 6 = 24 V DC input voltage (optional, power supply for fieldbus)
Pin 7 = 12 V DC output voltage
Pin 8 = Not used.
Pin 9 = Limit alarm OC/arc detect OC
Pin 10 = Operation OC
Pin 11 = Not used.
Pin 12 = Not used.
Pin 13 = Not used.
Pin 14 = External remote HV on/off - (minus)
Pin 15 = Ground
Pin 16 = Ground
Pin 17 = Ground
Pin 18 = Ground
Pin 19 = Ground
Pin 20 = 0 V (of 12V DC output voltage)
Pin 21 = Not used.
Pin 22 = Limit alarm OE/arc detect OE
Pin 23 = Operation OE
Pin 24 = Ground
Pin 25 = Ground

Table of Contents