8 Technical specifications
8.1 WaveNet in general
Number of devices
Also see
Addressing [}42]
.
Network mask
Number of Router-
Nodes
Number of LockNodes
8_8 Max. 249
Max. 249 per Router-
Node
11_5 Max. 1790
Max. 25 per Router-
Node
12_4 Max. 3200 Max. 9 per RouterNode
Transmission paths
Different WaveNet devices support different transmission paths (see
Item
numbers [}14]
).
25 kHz
B field for communication between:
Transponders and locking
devices
External LockNodes and locking
devices
868 MHz
SRD field for communication
between:
RouterNodes and LockNodes
RouterNodes and RouterNodes
Ethernet
Ethernet cabling for communication
between:
Computer and RouterNodes
RS-485
Bus cabling for connection to the
network:
RouterNodes
Wired LockNodes
Radio frequencies in the ISM band
Also see
Radio channel [}43]
.
WaveNet (Manual)
8. Technical specifications
203 / 210