WARNING
Change in the sequence of emergency functions due to malfunctions
SimonsVoss and "Made in Germany" stand for maximum safety and reliab-
ility. In individual cases, however, malfunctions of your devices cannot be
ruled out. This may pose a risk to the safety of persons and property, which
are additionally protected by the protective functions in the RingCast.
1. You should test your devices at least once a month (see
Device function
test [}178]
Shorter intervals may also be required according to other
regulations concerning your overall system).
2. Test the protective functions at least once a month (see
RingCast
function test [}136]
).
Locking devices and identification media
1. Activate the locking device.
9 Locking device is free-running.
2. Activate an authorised identification medium.
9 The locking device indicates authorised access (or battery warning,
then replace batteries).
9 Locking device opens when the battery condition is good.
3. Wait until the locking device disengages.
9 Locking device indicates disengagement (or nothing if battery is
low).
4. Activate an unauthorised identification medium.
9 Lockdevice indicates no authorisation (or battery warning, then
change batteries).
5. Check the battery level (see
Battery management [}184]
).
WaveNet devices
1. Check the signal quality (see
Check signal quality [}171]
).
2. Check accessibility (see
Test reachability (LSM) [}177]
and
Testing ac-
cessibility (WaveNet) [}174]
).
3. Check the battery level (see
Battery management [}184]
).
5.6.6 IO Status and LockNode responsiveness
You can check the following:
Signal at the respective input
Results of the last broadcast for each device
Status of the outputs
Analogue voltage present
WaveNet (Manual)
5. WaveNet Manager
179 / 210