Chapter 2. Installation/System Checkout
2-12
City Connect Module Wiring
City connect module mounts to the main system as
shown. Refer to City Module Installation Instructions
for details.
City module consists of two circuits that are jumper-
configured. Circuits may be configured for reverse-
polarity or local energy operation. See jumper setting
table for details. Modules must also be added to the sys-
tem configuration. See “System Options” later in this
manual.
All wiring to be per NFPA-72, NEC, and local codes.
Minimum 20 AWG for reverse polarity circuits; mini-
mum 18 AWG for local energy circuits.
Wiring is supervised for opens and grounds, but not
power-limited.
Conductors must test free of all grounds.
For specific information about reverse polarity and local
energy circuits see Figure 2-14.
If wiring is routed outside the building, use of a listed
secondary protector is required. Use Simplex Model
Number 2081-9044. A protector must be installed at
each location the wiring enters or exits a building. Each
2081-9044 adds 6 ohms wiring resistance and is rated
for 200 mA. Maximum wiring resistance is reduced by
6 ohms for each 2081-9044 used.
Circuits are shipped with 3.3K, 1/2W resistor installed.
Remove resistor before wiring circuit. Leave installed
on unused circuits.
Figure 2-14 City Connect Module Wiring
TB1
DANGER
HIGH VOLTAGE
IN THIS AREA
DACT TELEPHONE
CONNECTIONS
CITY CONNECT
MODULE
CITY CONNECT
MODULE
P6
1
2
3
4
CKT
1 CKT 2
SEE DETAIL A
P6 SELECTS CITY CIRCUIT 2 OPERATION.
POS. 1 - 2 AND 3 - 4 FOR CITY 2 TO
ACTIVATE ON SUPERVISORY CONDITION
REVERSE POLARITY LOCAL ENERGY
15mA MAX. AT 24VDC
24V DC NORMAL
4mA SUPERVISION CURRENT
500mA MAX. ALARM CURRENT (PULSED)
INTENDED FOR CONNECTION TO A POLARITY
REVERSAL CIRCUIT OF A REMOTE STATION
RECEIVING UNIT HAVING COMPATIBLE RATINGS
20 . 4V - 28VDC, 1/2 p - p RIPPLE (MAX.)
INTENDED FOR CONNECTION TO A 14 . 5 OHM
TRIP COIL.
MAXIMUM WIRING RESISTANCE: 4000 OHMS
WITH 2200 OHM TRIP COIL (6200 OHM TOTAL)
POLARITY MARKED ON TERMINALS REFLECTS
THE ALARM STATE.
POS. 1 - 3 FOR CITY 2 TO
ACTIVATE ON TROUBLE CONDITION
DETAIL A
TB2
3A
FUSE
SW SW
1
2 3 4
3A
FUSE
3A
FUSE
3A
FUSE
P3
P6
1
2
3
4
P6
1
2
3
4
LE
RP
LE
RP
LE
RP
LE
RP
P2 P4
P5
SW SW
1 2 3 4
1 2 3 4 5 6 7 8 1 2 3 4 5 1 2 3 4 5 6 7 8
TB3
MAIN SYSTEM BOARD - ADDRESSABLE (MSB - A)
JUMPER POSITIONS
CITY 1
P3: 1 - 2, 3 - 4, 5 - 6
P2: 2 - 3
P5: 1 - 2, 3 - 4, 5 - 6
P4: 2 - 3
P3: 7 - 8, 9 - 10
P2: 1 - 2
P5: 7 - 8, 9 - 10
P4: 1 - 2
REVERSE POLARITY LOCAL ENERGY
CITY 2
P5
LE
RP
LE
RP
P4
10 9
8 7
6 5
4 3
2 1
P3
LE
RP
LE
RP
P2
10 9
8 7
6 5
4 3
2 1
Employ a 14.5 Ohm Trip Coil
Technical Manuals Online! - http://www.tech-man.com
firealarmresources.com

Table of Contents

Related product manuals