Chapter 6: Power supply maintenance 53
Chapter 6: Power supply maintenance
This section contains the following topics:
About power supply maintenance guidelines
Remove a power supply
Install a power supply
Each server has two hot-swappable power supplies. If a power supply fails, replace it as soon as
possible.
About power supply maintenance guidelines
Follow these guidelines for maintaining power supplies:
You can replace a power supply without disrupting operations if an alternate, functioning power
supply is installed and connected to power.
For proper cooling, do not leave a power supply slot open. Do not remove a power supply until you
are ready to replace it.
A server can operate with only one functioning power supply. However, replace a failed or failing
power supply as soon as possible.
Replace a power supply only with a power supply of the same type and wattage. Contact Customer
Support for replacement power supplies.
Remove a power supply
Before you begin
Obtain a replacement power supply of the same type and wattage.
Read the guidelines for protecting hardware from electrostatic discharge.
Read the guidelines for maintaining power supplies.
Procedure overview
You should replace a failed, or failing, power supply as soon as possible.
Note:
Do not remove a power supply unless you have a replacement power supply that is ready to install.
Also, do not leave a power supply slot empty.