42
|
Autopilot | NSS Installation Manual
Autopilot
The Simrad NSS includes complete autopilot integration. When NSS is connected to a com-
patible Simrad Autopilot Computer (AC12, AC42, and SG05), you will have complete control,
setup and integration with your autopilot. The NSS display can be used in conjunction with
Simrad AP24, or AP28 Control units or the NSS can be used alone to conserve dash space.
Wiring the autopilot system
Using the AC12 or AC42 autopilot computer
The AC12/AC42 is connected to the NSS system using the SimNet network.
For more information about how to install and wire the autopilot, refer to the separate AC12/
AC42 Installation manual (part no 20222568).
OR
5 Amp Fuse
12 V DC
-
+
12-24 V DC
-
+
T
T
T
SimNet drop cable
SimNet Backbone
SimNet terminator
1
2
3
9
7
6
5
4
8
10
1 NSS Display
2 Pump / Drive (RPU160, RPU300, DD15, HDL2000x)
3 AC12 or AC42 Autopilot computer
4 RFU300 (Alternative option to RF25)
5 R3000X / S35 (optional steering controls)
6 DC Supply
7 SimNet 7 way Connector
8 RC42 Rate Compass
9 RF25 Rudder Feedback
10 Alarm Buzzer (optional)
12