SECTION 7 CARING FOR YOUR MACHINE
REMOVING AND REPLACING BOBBIN CASE
CAUTION: Before cleaning or adjusting
the machine, remove plug from the
socket outlet,
• Raise presser foot and needle.
• Open slide plate and remove bobbin.
• To remove the bobbin case, the needle
plate must be removed first.
• Lift needle plate (1) from right corner and
slide out from under foot.
4O
TO REMOVE BOBBIN CASE
• With a small screwdriver, turn lever (2)
back as far as it will go.
• Lift out bobbin case.
TO REPLACE THE BOBBIN CASE
• Guide forked end (3) of bobbin case
under feed (4).
• Draw rim of bobbin case under position
plate (5).
• Turn lever (2) toward you, locking bobbin
case in place.
NOTE: After locking case in place, be sure
it is not tight., but can move slightly.
• To replace needle plate, slide it under
pin (6) and push it to the left.
• Press needle plate down in place.
• Insert bobbin and close slide plate.