lb. kg lb. kg psi kPa psf
kg/m
2
min* 6400 2903 2560 1161 157.4 1085 206 1007
max* 8730 3960 3492 1584 175.41 1209 281 1373
min* 7661 3475 3064 1390 165.59 1142 247 1205
max* 9235 4189 3605 1635 181.36 1250 297 1452
60442AE-ANSI
*
**
NOTE:
MODEL
6832
Total Aerial Platform Load
6826
Total Aerial Platform
Weight
Wheel OUP**
min - Total aerial platform weight with no options
max - aerial platform weight + all options + full capacity
The LCP or OUP that an individual surface can withstand varies from structure to structure and is generally determined by the engineer or architect
for that particular structure.
LCP**
LCP – Locally Concentrated Pressure is a measure of how hard the aerial platform presses on the areas in direct contact with the floor. The floor
covering (tile, carpet, etc.) must be able to withstand more than the indicated values above.
OUP – Overall Uniform Pressure is a measure of the average load the aerial platform imparts on the whole surface directly underneath it. The
structure of the operating surface (beams, etc.) must be able to withstand more than the indicated values above.