SKYJACK, Page 28
SJ800 - E Series
Battery Powered
Section 2 - List of Tables
General Maintenance
Before attempting any repair work, disconnect battery by turning main power disconnect switch to off
position. Preventive maintenance is the easiest and least expensive type of maintenance.
Table 2.6c Maintenance and Inspection Schedule - AS
Frequency
Daily
3 months or
150 hours
Yearly
Frequency
Daily
3 months or
150 hours
Yearly
Base
Labels A Base Weldment A
Electrical A Wheel/Tire Assembly A
Limit Switches A Steer Cylinder Assembly A
Hydraulic A Splitter Manifold A
Engine Compartment Tie Rod A
Main Power Disconnect Switch A Emergency Lowering Access Rod A
Base Control Switches A Ladder A
Tilt Sensor A Outriggers A
Battery A Function Tests
Hydraulic Pump A Test Main Power Disconnect Switch A
Radiator A Base Control Console
Muffler and Exhaust A Test Platform/Engine/Base Key Switch A
Engine Pivot Tray A Test Emergency Stop A
Engine Oil Level A Test Platform Raise/Lower Switch A
Fuel Shut-off Valve A Test Emergency Lowering A
Engine Air Filter A Test Free-wheeling A
Fuel Leaks A Platform Control Console
Hydraulic/Fuel Compartment Test Emergency Stop A
Hydraulic Tank A Test Enable Trigger Switch A
Hydraulic Oil A Test Platform Raising/Lowering A
Hydraulic Return Filter A Test Steering A
Fuel Tank A Test Driving A
Fuel Leaks A Test Speed Limit A
Main Manifold A Test Brakes A
Gear Type Flow Divider A Test Horn A
Platform Assembly A Test Tilt Sensor A
Lanyard Attachment Anchors A
60601AA-AS
AC Outlet on Platform A
Manuals A
Platform Control Console A
Lifting Mechanism
Maintenance Support A
Scissor Assembly A
Scissor Bumpers A
Rollers A
Lift Cylinder(s) A
* - Maintenance must be performed only by trained and competent personnel who are familiar with mechanical procedures.
B*
Visual and Daily Maintenance Inspections
A - Perform Visual and Daily Maintenance Inspections & Functions Test. Refer to Section 2.8 and Section 2.9 of the operating manual.
B - Perform Scheduled Maintenance Inspection. Refer to Service & Maintenance manual.
B*
B*
WARNING
Use original or manufacturer-approved parts and components for aerial platform.
Go to Discount-Equipment.com to order your parts