EasyManua.ls Logo

Skyjack Compact Rough Terrain Series - Page 82

Skyjack Compact Rough Terrain Series
264 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SKYJACK, Page 83
SJRT Compact Series
Engine Powered
9. Loose or broken wire #63 from outrigger board to outrigger limit switch (LS62).
- Check continuity. Replace if defective.
10. Defective Limit Switch (LS62).
- Check switch. Replace if defective.
11. Loose or broken wire #62 from outrigger limit switch (LS62) to outrigger board.
- Check continuity. Replace if defective.
12. Loose or broken wire #62 from outrigger board to outrigger limit switch (LS61).
- Check continuity. Replace if defective.
13. Defective outrigger limit switch (LS61).
- Check switch. Replace if defective.
14. Loose or broken wire #61 from outrigger limit switch (LS61) to outrigger board .
- Check continuity. Replace if defective.
15. Open diode (D36) on outrigger board.
- Check diode. Replace if defective.
4.1-26. Platform Will Not Lift From Platform or Base Controls With Outriggers
Extended
1. Outriggers not extended enough.
- Extend outriggers to take weight off tires (refer to operator section).
2. Loose or broken wire #10A from base terminal block (TB1) to pin #15 on connector (CN22) at the
outrigger board.
- Check continuity. Replace if defective.
3. Loose or broken wire #10A from outrigger board to outrigger limit switch (LS68).
- Check continuity. Replace if defective.
4. Defective outrigger limit switch (LS68).
- Check switch. Replace if defective.
5. Loose or broken wire #68A from outrigger limit switch (LS68) to outrigger board.
- Check continuity. Replace if defective.
6. Loose or broken wire #10A from outrigger board to outrigger limit switch (LS67).
- Check continuity. Replace if defective.
7. Defective outrigger limit switch (LS67).
- Check switch. Replace if defective.
8. Loose or broken wire #67A from outrigger limit switch (LS67) to outrigger board.
- Check continuity. Replace if defective.
9. Loose or broken wire #10A from outrigger board to outrigger limit switch (LS66).
- Check continuity. Replace if defective.
10. Defective outrigger limit switch (LS66).
- Check switch. Replace if defective.
11. Loose or broken wire #66A from outrigger limit switch (LS66) to outrigger board.
- Check continuity. Replace if defective.
12. Loose or broken wire #10A from outrigger board to outrigger limit switch (LS65).
- Check continuity. Replace if defective.
13. Defective outrigger limit switch (LS65).
- Check switch. Replace if defective.
14. Loose or broken wire #65A from outrigger limit switch (LS65) to outrigger board.
- Check continuity. Replace if defective.
15. Check for power on wire #65 at outrigger control module at pin P2-8.
- If no voltage present, proceed to Outrigger Control Module Troubleshooting.