4.1-32. All Outriggers Inoperative (Auto Level Only)
A: Led Power Indicator Light at Outrigger Control Module (OCM1) Not On
(Constant)
1. Loose or broken wire #10A from pin #1 of the tilt switch connector to pin P2-12 on the outrigger
control module (OCM1).
- Check for continuity. Replace if defective.
2. Loose or broken wire # 10A from pin #1 of the tilt switch connector to base terminal block (TB1).
- Check for continuity. Replace if defective.
3. Loose or broken wire # 02 from pin #3 of the tilt switch connector to pin P2-11 on the outrigger
control module (OCM1).
- Check for continuity. Replace if defective.
4. Loose or broken wire # 02 from pin #3 of the tilt switch connector to base terminal block (TB1).
- Check for continuity. Replace if defective.
5. Defective outrigger control module (OCM1).
- Replace.