SLAYER STEAM X USER MANUAL
offset value.
If the displayed brew temperature is lower than the actual brew
temperature, increase the offset value. If the displayed brew temperature is
higher than the actual brew temperature, decrease the offset value.
5. Press and release the jog wheel to confirm your new setting and proceed to the
next step.
6. Repeat steps 4-5 for all remaining settings:
Gp2 (on 2-group, right brew tank; on 3-group, middle brew tank)
Gp3 (rightmost brew tank; 3-group only)
7. Press and release the jog wheel to confirm your new setting and return to the
menu for additional adjustments OR move the brew actuator Left to Right to
save and exit the Advanced Menu.
SET LANGUAGE
1. Press and hold the jog wheel above the left grouphead for five seconds to
activate the Advanced Menu options.
2. Rotate the jog wheel clockwise until the “Language” setting appears.
3. Press and release the jog wheel to enter the “Language” setting.
4. Scroll to select your desired Language.
5. Press and release the jog wheel to cofirm your language and return to the menu
for additional adjustments OR move the brew actuator Left to Right to save and
exit the Advanced Menu.
CALIBRATE YOUR FLOW METERS
1. Press and hold the jog wheel above the left grouphead for five seconds to
activate the Advanced Menu options.
2. Rotate the jog wheel clockwise until the “FlowMeter Calib. setting appears.
3. Press and release the jog wheel to enter the “FlowMeter Calib setting.
Adjust this value up or down based on the need to increase or decrease the
water volume.
Factory settings will not fit every recipe, therefore fine tuning your
volumetrics to match the output on your scale is the best way to acheive
consistency
4. Once you have acheived your desired value, press the jog wheel to save. You
will immediatley be prompted to enter a value for Group 2 and Group 3 (if
applicable).
5. Press and release the jog wheel to confirm and save the settings.