SLAYER STEAM EP USER MANUAL V1.1 | SEPTEMBER 11, 2018 27
NOTE: Programming the brew volume does not aect your preinfusion
settings however it will aect your extraction. Adjust the grind
accordingly.
Brew Group Temperature
Brew tank temperatures are measured in real-time at each group head
and displayed in degrees Fahrenheit or Celsius, depending on saved
preference. Adjustable in tenth-degree (0.1-degree) increments
• Minimum setting: 82° C (180° F)
• Maximum setting: 97° C (206° F)
SCREEN EXAMPLE:
Temperatures
Depress to Select
SCREEN EXAMPLE:
Temperature
Gr: 1 <201>F
1. Working from the left group will enables the ability to copy the
temperature to all groups.
2. Copy all Groups < YES > prompt will only occur when programming
values with the Master (Left) group. By selecting NO, proceed by
individually programming brew group temperatures as desired.
3. Exit the menu when programming is completed across all groups
Programmable Pre-Wet
Pre-Wet is a feature designed to maximizing extraction through the
reduction of channeling. It is disabled upon arrival with both the Pre-Wet
and Hold timed values set to zero. Pre-Wet can be set independently on
all 4 buttons on each group. The bracket on the left “Pre Wet” showcases
the time the valve is open or “wetting” allowing water to enter the brew
chamber, up to four seconds. The bracket on the left showcases the time
the valve is closed or the “Hold” time, up to four seconds.
PROTIP: For an eective wetting and hold cycle you must choose a pre-
wet and hold value otherwise the extraction will proceed as a normal shot,
void of pre-wet.
1. Scroll to the Pre-Wet screen and select
2. All the buttons will blink ON/ OFF prompting a button selection for
programming.
SCREEN EXAMPLE:
Pre-Wet
Choose Button
3. Selecting a button, now program the lit button of choice.
4. Two values will appear, program a value between 1 and 4 seconds in
Pre-Wet.
5. Program a value for water to be paused in the Hold column between 1
and 4 seconds.
SCREEN EXAMPLE:
Pre-Wet Hold
<2 s> 1 s
6. Save by pressing the menu button and follow the prompts to set the
Pre-Wet for all brew buttons.
NOTE: When the left Control Group window is open for programming
the display will prompt “Copy all Groups” display. If YES is chosen the
Pre-Wet setting for the button will copy to the same corresponding button
across all groups. For example if the Pre-Wet setting for group 1, button 1,
single press is chosen and YES is selected to Copy all Groups, this value
will copy over across all groups, at button 1, single press. Double press to
program buttons 3 and 4 across all corresponding groups.