7 Commissioning
SMA Solar Technology AG
Operating manualEDMM-10-BE-en-2740
☐ The respective latest version of one of the following web browsers must be installed on the
smart device: Chrome, Edge, Firefox or Safari.
☐ JavaScript must be enabled in the web browser of the smart device.
Procedure:
1. First, establish a direct connection via Ethernet Establishing a Direct Connection via Ethernet.
2. Select Change network configuration. Observe that the manual network configuration is
set by default.
3. Set the network interface LAN1 or LAN2 and select [Yes].
☑ This automatically configures the network settings via DHCP server.
4. Close the web browser of your end device, open again and enter the product's access
address in the address bar of the web browser. Then press the Enter key.
5.
Web browser displays warning
After the access address of the product has been entered, a message might appear
indicating that the connection to the user interface of the product is not secure.
• Continue loading the user interface (scroll to bottom and click proceed/advance).
☑ The login page of the user interface opens after a few seconds.
7.3 Commissioning the Product
After you have connected the product with the local network, the login page of the user interface
opens.
Figure 8: Login page of the user interface
Requirements:
☐ All devices in the local network must be in operation and connected to the product via an
Internet router.
☐ There must be an active Internet connection.
☐ An NTP server must be available in the local network or via the Internet. If there is no NTP
server available, the time set in the web browser can be used as system time.