6.2 Overview of the Connection Area
CD
A
B
H
G
F
E
Figure 6: Connection areas and enclosure openings at the bottom of the inverter
Position Designation
A Positive DC connector
B Negative DC connector
C RJ45 pin connector for the network cable
D Pin connector for the AC connector
E Connection of the grounding terminal for additional grounding
F Cable gland for the AC cable
G Cable gland with filler plug for the network cable
H Connection cap
6.3 AC Connection
6.3.1 Requirements for the AC Connection
Cable requirements:
External diameter: 5mm to 13mm
Conductor cross-section: 1.5mm² to 4mm²
Insulation stripping length: 15mm
Sheath stripping length: 70mm