SMA Solar Technology AG Parameter List Overview
Technical Description SI2012_2224-TEN082311 165
140# Meter SIC40
If one or more SIC40 charge controller is connected to the island grid communication, the following
menus will appear on the display:
134 05 ExtPwrRt kVAr reactive power of external source
135 # Meter Slave 1
135 01 ExtPwrAtSlv1 kW active power of external source at slave1
135 02 ExtVtgSlv1 V voltage of external source at slave1
135 03 ExtCurSlv1 A current of external source at slave1
135 04 ExtPwrRtSlv1 kVAr reactive power of external source at slave1
136# Meter Slave 2
136 01 ExtPwrAtSlv2 kW active power of external source at slave2
136 02 ExtVtgSlv2 V voltage of external source at slave2
136 03 ExtCurSlv2 A current of external source at slave2
136 04 ExtPwrRtSlv2 kVAr reactive power of external source at slave2
Menu
nr.
Parame
ter.Nr.
Parameter Name Range/Unit Description
141# SIC40 Total
141 01 TotSicPvPwr W Total power of all SIC40s
141 02 TotSicBatCur A Battery current of all SIC40s
142# SIC40 1
142 01 Sic1PvPwr W PV power of first SIC40
142 02 Sic1PvVtg V PV voltage of first SIC40
142 03 Sic1BatVtg V Battery voltage of first SIC40
142 04 Sic1BatCur A Battery current of first SIC40
142 07 Sic1HsTmp °C Temperature of first SIC40's heat sink
142 09 Sic1SWVers SW version number SIC-PB
143# SIC40 2
143 01 Sic2PvPwr W PV power of second SIC40
143 02 Sic2PvVtg V PV voltage of second SIC40
143 03 Sic2BatVtg V Battery voltage of second SIC40
143 04 Sic2BatCur A Battery current of second SIC40
143 07 Sic2HsTmp °C Temperature of second SIC40's heat sink
143 09 Sic2SWVers SW version number SIC-PB