-39-
No.PS##-OML0003-B
■[F97] Selection of copy function
The set values of pressure and functions (except for corrected value of fine adjustment of display value) can
be copied. When the pressure range and output and unit specifications are the same, this function becomes
available. The set value can be copied up to 10 Pressure switches simultaneously.
<Connection>
Connect the Pressure switches after turning off the power supply.
Connect the FUNC terminals of the master Pressure switch and the slave Pressure switches and turn on
the power supply.
The master Pressure switch is the switch from which the setting is copied.
The slave Pressure switch is the switch to which the setting is copied.
<Operation>
Press the
or button of the master Pressure switch in function selection mode to display [F97].
Press the button.
Move on to the selection of copy function.
Press the button to set.
Selection of copy function
Press the
or
button to select copy function.