8. Anomalies and failures - how to remedy
Once the problem has been solved, it will be possible to exit this state by pressing the
[ESC] key.
PROBLEM 1: Cooling fin overtemperature.
Solution:
• Check the board heatsink cooling fan
• Check that the electrical panel air intakes are not obstructed
• If the problem continues, switch power off and contact the service centre.
PROBLEM 2: Temperature reading outside the set limits.
Solution:
• Check the thermocouple operation
• Check the thermocouple linking cable
• Check connection cable
• If the problem continues, switch power off and contact the service centre.
PROBLEM 5: Problem with the closed micro pusher.
Solution:
• Check the micro operation (SQ4) or decrease the pusher speed.
• Check the pneumatic circuit pressure
• Check the cylinder operation
• If the problem continues, switch power off and contact the service centre.
PROBLEM 7: Incorrect configuration.
Solution:
• Re-set the machine model from menu reserved to re-program the board
• If the problem continues, switch power off and contact the service centre.
PROBLEM 8: Data reading problem
Solution:
• A problem with the microprocessor has occurred, therefore the board must be
changed
PROBLEM 9: The sealing bar end stop has not been detected.
Solution:
If the sealing bar does not move:
• Check the pneumatic circuit pressure
Fig. 8.2.1
problem 1