Your settings
Menu items and submenu items Presettings Your settings
Default image display HI-MAT+
Maximum zoom factor 1...16 times 8
Continuous zoom on
Zoom interpolation on
Screen saver after 1...30 minutes (0 = off) 0
Location menu
Location AIRPORT
Subsite GATE
View/monitor assignment standard
Position main monitor left
Audible baggage marking alarm [1...10 sec] (0 = off) 1
Buffer time in case of power failure [1...20 min] 3
Scanning functions (F 2-35)
Forbidden image display modes during conveyor run
Superenhancement off
All image display modes except for Superenhance-
ment and Zoom
on
Zoom on
Operating mode One-way
Scanning direction standard/forward
Reverse scanning off
Reverse key locking off
Forward key locking on
Releasing conveyor keys is ignored for 0...3 seconds 0
Continuous scanning off
For cutless images conveyor reverses at Start
Recheck/external image evaluation (F 2-42)
Store images - if unsuspicious off
Store images - if suspicious off
Store images - after timeout off
Maximum recheck/evaluation time [10...9999 sec]
(0 = off)
0
Image transmission method Screen
Transmit images on
Automatic detection (F 2-39)
X-ACT on
Detection class [1...30] 1
High Density Alert HDA on
Minimum absorption [0...100%] 95
Minimum size [0.1...10000cm²] 100
HI-SPOT on
Minimum absorption [0...100%] 90
95587413 01/01/09 © Smiths Heimann