36
10 Batch processing (further details see also manual 3025 Chapter 7.10)
Batch code 4 parameter
source
as Batch code 1 parameter source
Batch code 5 parameter
source
as Batch code 1 parameter source
Batch
activation key Selection
> No key
> Print key
> Enter key
Factory setting: No key
Pause between
batch code 1 - 2
Input
Time for the pause between the batch codes, numeric via numeric keypad
Factory setting: 100 ms
Pause between
batch code 2 - 3
Input
Time for the pause between the batch codes, numeric via numeric keypad
Factory setting: 100 ms
Pause between
batch code 3 - 4
Input
Time for the pause between the batch codes, numeric via numeric keypad
Factory setting: 100 ms
Pause between
batch code 4 - 5
Input
Time for the pause between the batch codes, numeric via numeric keypad
Factory setting: 100 ms
Pause after end Input
Time for the pause at the end, numeric via numeric keypad
Factory setting: 100 ms
11 IO-control (further details see also manual 3025 Chapter 7.11)
IO - mode Selection
> off
> on
> on, safety function
Factory setting: off
Outputs Selection for the assignment of the individual switching points
> Switching point S1
> Switching point S2
> Switching point S3
> Switching point S4
> Switching point S5
> Switching point S6
Factory setting: all not active
Inputs Selection for the assignment of the individual inputs
> Input E1
> Input E2
> Input E3
> Input E4
Factory setting: all not active