48
Selection of existing fixed values from the database
Scroll with the arrow keys F3 and F4,
Call the desired fixed value with F6 Edit
Editing an existing fixed value from the database
Press F6 to call up editing of the selected fixed value.
Parameter number is highlighted, call via F6 Edit, input via number/alpha keyboard. Accept the input with F6.
(Cancel without accepting the entry with F5 Back.)
Mark the respective parameter entry, call up via F6 Edit, input via numbers/alpha keyboard. Accept the entry
with F6.
(Cancel without accepting the entry with F5 Back.)
Deleting an existing fixed value
Scroll with the arrow keys F3 and F4
Delete the marked fixed value with F2 Delete.
The resulting gap in the consecutive numbering is closed.
Create new fixed value
Press F1 New.
The memory location number is assigned by the terminal. The first number in brackets indicates the free
memory locations, the second number the occupied memory locations.
Parameter number is marked, call via F6 Edit, input via number/alpha keyboard. Accept the entry with F6.
(Cancel without accepting the input with F5 Cancel).
Mark respective parameter entry, call via F6 Edit, input via numbers/alpha keyboard. Accept the entry with F6.
(Cancel without accepting the entry with F5 Cancel).
Exiting the database
Press F5 back to exit the list.
Database maintenance via optional Soehnle Professional user software 3025
For the requirement of a simple and multiple application to the care of the Org data base for the designations
and contents there is the PC - user software 3025.
The user software is connected to the PC via the EDP interface RS232, USB or Ethernet with the respective
connection cable. In addition to the Windows-based user software, the Microsoft Excel spreadsheet software
is also required.
Open database to use the fixed values
Call up the desired organisation data memory with the ORGA - ORGD key.
Press the F1 Database key. Selection within the list:
Scroll with the arrow keys, call the desired fixed value with F6 Apply.
Direct call via memory location or article number.
Use the numeric keypad to enter the memory location or article number to call up the corresponding fixed
value.
You can define whether the memory location or article number is to be called up in the setting mode under
Setting mode / Terminal / Organisation data / Call fixed values.
Display the content for the complete multiline database entry.
Call up the desired organisation data memory with the ORGA - ORGD key.
Press the F2 Info lines key to display the complete contents of the currently active memory.