3 Counting
Default IO configuration Selection do not execute or execute
Execute activates the switching functions for an external control light or controller.
To control the switching operations, an I/O card must be installed.
Start mode Selection off or on.
When the start mode is activated, the scale freezes the value and thus the signal
once the activated switching points have been reached. The scale can then be
unloaded without deactivating the switching point and thus unintentionally starting
a new process. Only by pressing the F6 Start key in the Control functions level is
the frozen status released.
Factory setting: off
Display information field Selection of which data is to be displayed in the information field
> Counting: Toggle between the individual functions used, counting with the
reference weight and weight value in gross / net, e.g. control light, totalising
memory.
> Control display: Continuous display of the traffic light function.
> Total: Continuous display of the totalising memory.
> Last item: Continuous display of the last item.
> ORG data + database: Continuous display of the organizational data memory.
> Fixed values for reference weight: Continuous display of the reference weight
memory activated.
> Show barcode: Continuous display of the scanned bar code.
> Code128 Weight value: Display bar code128 with the current stability weight
value or counter value.
Factory setting: Counting
Factory settings Execute selection resets all settings to factory defaults.