PowerMagic 400V C&I Energy Storage System User Manual
55
Crimping pliers
Cutting pliers
Netting pliers
Fibre optic stripper
Figure 5.1 Installation Tools
5.2.2 Prepare Cables
Table 5.1 Cable preparation table
Name
Type
Scope of cross-
sectional area
selection
Terminal
Remarks
The PCS AC
input power cord
3 core (A, B, C)
outdoor copper
core wire or
choose armored
cable
95mm²*3
The M 8 OT / DT
terminal
Storage cabinet PCS
AC input three-
phase power line
DC-parallel
cabinet power
line
Random cabinet
comes with it
DC+:70mm²
DC-:70mm²
The cable comes
with a power
terminal
Energy storage cabinet
and battery cabinet
when used
Connection
cabinet signal
line
Random cabinet
comes with it
Energy storage
cabinet and battery
cabinet when used
The RS485
communication
line
2 Core
shielding line
0.5~1.5mm²
*2
Tube type cold
pressure end +
specified pin
Choose according to
the actual
configuration
The CMU
communication
network line
CAT 5E
Outdoor
shielded
network cable,
with an internal
resistance of
1.5 Ω / 10m
Shield of the RJ 45
crystal head
When the energy
storage cabinet does
not integrate CSU,
CMU to CSU
The CSU
CAT 5E
Shield of the RJ 45
When the energy