EasyManuals Logo

SolarEdge EV Series User Manual

SolarEdge EV Series
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #53 background imageLoading...
Page #53 background image
Communication Status
This screen displays the status of connection option(s): LAN, RS485, cellular or ZigBee
Plug-in.
Communication
LAN
Connected
RS485-1
Modbus
2 of 2
RS485-2
SE Slave
None
Cellular
N/A
ZigBee
NC
For each communication option, one of the following statuses is displayed:
Connected: The inverter established a successful connection and communication
with the specified server port
NC: Not Connected
S_OK: The connection to the monitoring platform is successful (should appear only
if the is connected to the server)
N/A : Not Applicable
x of y: Number of devices connected out of all devices
Temporarily displayed (with a clock sign):
Initializing communication
Connecting to a network
Connecting to SolarEdge servers
Error message (with the sign)
EV Charging Single Phase Inverter Guide MAN-01-00588-1.1
52 Viewing System Status

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge EV Series and is the answer not in the manual?

SolarEdge EV Series Specifications

General IconGeneral
AC Frequency60 Hz
Protection RatingIP65
AC Voltage208/240 V
EV Charger Output Voltage208/240 V
EV Charger Max. Output Current32 A
CommunicationEthernet, Wi-Fi
SafetyUL1741
Operating Temperature Range-25°C to 60°C