Chapter 2: Installing the Power Optimizer
Safety
The following notes and warnings apply when installing the power optimizers. Some of
the following may not be applicable to smart modules:
WARNING!
When modifying an existing installation, turn OFF the inverter ON/OFF/P
switch, the Safety Switch (if applicable) and the AC circuit breaker on the main
AC distribution panel.
CAUTION!
Power optimizers are IP68/NEMA6P rated. Choose a mounting location where
optimizers will not be submerged in water.
CAUTION!
This unit must be operated according to the operating specifications provided
with the unit.
CAUTION!
Cutting the power optimizer input or output cable connector is prohibited and
will void the warranty.
CAUTION!
All PV modules must be connected to a power optimizer.
CAUTION!
If you intend to mount the optimizers directly to the module or module frame,
first consult the module manufacturer for guidance regarding the mounting
location and the impact, if any, on module warranty. Drilling holes in the
module frame should be done according to the module manufacturer
instructions.
Chapter 2: Installing the Power Optimizer 15
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5

Table of Contents

Other manuals for SolarEdge SE6000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE6000H and is the answer not in the manual?

SolarEdge SE6000H Specifications

General IconGeneral
ModelSE6000H
ManufacturerSolarEdge
AC Output Power6000 W
Rated AC Power6000 W
CoolingNatural Convection
Noise Level< 25 dBA
TopologyTransformerless
Number of MPP Trackers1
Warranty12 years
Max. Input Voltage480 V
MPPT Voltage Range380 - 480 V
Operating Temperature Range-25°C to 60°C
Dimensions450 x 370 x 174 mm
Weight23.6 lbs (10.7 kg)
AC Voltage208/240 V