EasyManuals Logo

SolarEdge SE6000H User Manual

SolarEdge SE6000H
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
NOTE
Only the first and last SolarEdge devices in the chain should be terminated.
The other inverters in the chain should have the termination switch OFF
(down position).
11. If not using surge protection, connect the grounding wire to the first inverter in the
RS485 chain; make sure the grounding wire is not in contact with other wires. For
inverters with a Connection Unit, connect the grounding wire to the grounding bus-
bar in the Connection Unit.
Verifying the Connection
After connecting and configuring a communication option, perform the following
steps to check that the connection to the monitoring server has been successfully
established.
1.
Go to Commissioning >Status.
2. In the Summary section, under Server Comm., make sure S_OKis displayed
together with the selected communication option.
3.
Scroll down to the Communication section and check that the communication
options are as required.
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5
60 Verifying the Connection

Table of Contents

Other manuals for SolarEdge SE6000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE6000H and is the answer not in the manual?

SolarEdge SE6000H Specifications

General IconGeneral
ModelSE6000H
ManufacturerSolarEdge
AC Output Power6000 W
Rated AC Power6000 W
CoolingNatural Convection
Noise Level< 25 dBA
TopologyTransformerless
Number of MPP Trackers1
Warranty12 years
Max. Input Voltage480 V
MPPT Voltage Range380 - 480 V
Operating Temperature Range-25°C to 60°C
Dimensions450 x 370 x 174 mm
Weight23.6 lbs (10.7 kg)
AC Voltage208/240 V