IMPORTANTSAFETYINSTRUCTIONS
SAVETHESEINSTRUCTIONS
WARNING!
When using electric products, basic precautions should always be followed,
including the following. This manual contains important instructions that shall
be followed during installation, operation and maintenance of the unit.
a. Read all the instructions before using this product.
b. This device should be supervised when used around children.
c. Do not put fingers into the electric vehicle connector.
d. Do not use this product if the flexible power cord or EV cable is frayed, has
broken insulation, or any other signs of damage.
e. Do not use this product if the enclosure or the EV connector is broken,
cracked, open, or shows any other indication of damage.
1. An insulated grounding conductor that is identical in size, insulation
material, and thickness to the grounded and ungrounded branch-circuit
supply conductors, except that it is green with or without one or more
yellow stripes, shall be installed as part of the branch circuit that supplies the
device or system.
2. The grounding conductor described in item 1 shall be grounded to earth at
the service equipment or, when supplied by a separately derived system, at
the supply transformer.
WARNING!
The inverter cover must be opened only after switching the inverter ON/OFF/P
switch located at the bottom of the inverter to OFF. This disables the DC voltage
inside the inverter. Wait five minutes before opening the cover. Otherwise, there
is a risk of electric shock from energy stored in the capacitors.
EV Charging Single Phase Inverter Guide MAN-01-00583-1.5
6 IMPORTANTSAFETYINSTRUCTIONS

Table of Contents

Other manuals for SolarEdge SE6000H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge SE6000H and is the answer not in the manual?

SolarEdge SE6000H Specifications

General IconGeneral
ModelSE6000H
ManufacturerSolarEdge
AC Output Power6000 W
Rated AC Power6000 W
CoolingNatural Convection
Noise Level< 25 dBA
TopologyTransformerless
Number of MPP Trackers1
Warranty12 years
Max. Input Voltage480 V
MPPT Voltage Range380 - 480 V
Operating Temperature Range-25°C to 60°C
Dimensions450 x 370 x 174 mm
Weight23.6 lbs (10.7 kg)
AC Voltage208/240 V