30
Search settings for devices connected via Ethernet
Fig. 16: Menu: Search settings for an Ethernet connection
If your devices are connected to the MaxWeb XPN via Ethernet, please enter the following
search settings:
Select connection: Select the menu item “Ethernet”.
IP address: Enter the IP address under which the devices are connected.
TCP port: Enter the TCP port (from 1064 to 65535) for communication with
the connected devices. The same TCP port must also be set on the
inverters.
Timeout: Enter a timeout for the device search in ms. We recommend you set a
longer timeout for networks under high load.
Start address /
End address:
Enter the start and end address (from 1 to 249) for the address range
within which devices are to be searched for. Every device must have
its own address.
Device search: Click on the button “Start device search” to search for your connected
devices. Once the search is completed, the following message
appears:
Complete
The “Search results” window shows a list of the devices found.