Technical Data
24
4.4 Battery Data
Model
X1-HYB-
3.0-LV
X1-HYB-
3.7-LV
X1-HYB-
4.0-LV
X1-HYB-
4.6-LV
X1-HYB-
5.0-LV
X1-HYB-
6.0-LV
Battery type Lithium/Lead-Acid
Battery voltage range [V] 40~60
Nominal Battery Voltage[V] 48
Max. Charging Voltage[V] <=60 (Adjustable)
Max. Charging/Discharging Current[A] 75 120
Charging Strategy for Li-Ion Battery Self-adaption to BMS
Charging Strategy for Lead-Acid Battery 3 stages curve
Temperature Sensor Optional
4.5 System Data
Model
X1-HYB-
3.0-LV
X1-HYB-
3.7-LV
X1-HYB-
4.0-LV
X1-HYB-
4.6-LV
X1-HYB-
5.0-LV
X1-HYB-
6.0-LV
MPPT Eciency >99.9%
Max. eciency [%] 97.6
Euro. eciency [%] 97.0
Battery charge/discharge eciency [%]² 96.0/95.0
Model
X1-HYB-
3.0-LV
X1-HYB-
3.7-LV
X1-HYB-
4.0-LV
X1-HYB-
4.6-LV
X1-HYB-
5.0-LV
X1-HYB-
6.0-LV
Anti-Islanding Protection Yes
PV String Input Reverse Polarity Protection Yes
Insulation Resistor Detection Yes
Residual Current Monitoring Unit Yes
Output Over Current Protection Yes
Output Short Protection Yes
Output Over Voltage Protection Yes
Surge Protection AC Type III/DC Type III
Battery Terminal Temp Protection Yes
4.6 Protection Device