Electrical Connections
45
Note!
Please ensure that the BAT power line and BMS communica-
tion line are correctly connected when using the low-voltage
batteries TP-LR25 and TP-LR36. Check T-BAT LR25 & T-BA
LR36 Installation Manual for details.
Power line connection
Communication line connection
CAN/RS485
Low voltage lithium battery
Non-polar DC MCB
6.3 Battery Connection
6.3.1 Battery connection requirements
Battery Breaker
Battery connection diagram
The series inverter system can be equipped with low voltage lithium battery
and lead acid battery.
Before connecting the battery, a non-polar DC MCB must be installed to en-
sure safety.
Before maintenance, the inverter need to be safely disconnected.
Model
X1-HYB-3.0-
LV
X1-HYB-3.7-
LV
X1-HYB-4.0-
LV
X1-HYB-4.6-
LV
X1-HYB-5.0-
LV
X1-HYB-6.0-
LV
Voltage Nominal voltage of DC breaker should be larger than maximum voltage of battery.
Current[A] 100 A 150 A
Model
X1-HYB-
3.0-LV
X1-HYB-
3.7-LV
X1-HYB-
4.0-LV
X1-HYB-
4.6-LV
X1-HYB-
5.0-LV
X1-HYB-
6.0-LV
Recommended
battery power (kWh)
3~4.5 3.7 ~ 5.55 4.0 ~ 6.0 4.6 ~ 6.9 5.0 ~ 7.5 6.0 ~ 9.0