Electrical Connections
35
The series inverters have two PV inputs. Select photovoltaic modules with
good performance and quality assurance. The open circuit voltage of the
module array should be less than the maximum PV input voltage specied
by the inverter, and the working voltage should be within the MPPT voltage
range.
6 Electrical Connections
6.1 PV Connection
Warning!
The voltage of photovoltaic modules is very high, and is danger-
ous voltage. When wiring, follow the safe electricity regulations.
Caution!
Do not ground the positive or negative pole of the photovoltaic
module!
Note!
The following PV module requirements need to be applied to
each input range:
1. Same model
2. Same quantity
3. The same angle
Model
X1-HYB-
3.0-LV
X1-HYB-
3.7-LV
X1-HYB-
4.0-LV
X1-HYB-
4.6-LV
X1-HYB-
5.0-LV
X1-HYB-
6.0-LV
Max. PV input voltage
550V
Start output voltage
110V
Nominal input voltage
360V
MPPT voltage range
80V ~ 520V
Note!
The series inverters support the following PV module connection modes.
Method 1: Multi
+
-
+
-
PV 1
PV 2
Inverter