Page 42
8 Troubleshooting
Trouble
Cause
Remedy
Section
Low Flow / Pressure
/ Vacuum
Blower rotating backwards (Incorrect wiring)
Reverse motor wiring
5.1
Dirty or contaminated filter
Clean or replace filter element
7.1
Collapsed flexible hose lining
Use only reinforced flexible hose
1.2
Air leaks in the system
Fix leaks
4
Closed or damaged valve
Open or replace valve
1.2
Worn or damaged impeller
Replace impeller and inspect blower housing
7.1
Drive belt slipping (Contaminated or damaged)
Replace belt
Replace pulleys
Clean pulleys
4.3, 7.3
7.1
7.1
Worn pulley
Replace worn pulleys
7.1
Wrong pulley size
Contact Sonic
Cover
Wrong drive belt (Not Sonic approved)
Use only Sonic supplied belts
4.3, 7.3
Incorrect piping design (Too small)
Increase piping diameter
Contact Sonic for design assistance
4
Cover
Improper blower size for application
Contact Sonic for design assistance
Cover
Frequent Drive Belt
Failure
Blower rotating backwards (Incorrect wiring)
Reverse motor wiring
5.1
Motor pulley wobbling
Replace motor
Replace motor bushing
Replace motor pulley
5.1, 7.1
7.1
7.1
Frequent start / stops without soft start controller
Install soft start motor controller
Install diverter valve and run continuously
5.1
5.1
Motor pulley out of alignment
Realign motor pulley
Replace mounting bracket if damaged
7.1
7.1
Pulley grooves worn
Replace pulley
7.1
Hostile environment (belts contaminated)
Locate blower in safe location
Purchase Sonic blower enclosure
4.2
4.2
Wrong belts (Not Sonic approved)
Use only Sonic supplied belts
4.3, 7.3
Incorrect belt installation method
Properly install belts
4.3, 7.3
Worn belt tensioner
Replace belt tensioner
7.1
Liquid entering blower inlet (impeller stall)
Locate blower in safe location
Install inline filters
4
4
Electrical
Overloading
Exceeding rated CFM
Contact Sonic
Cover
Blower RPM too high (Blower pulley too small)
Contact Sonic
Cover
Motor has winding or bearing damage
Replace motor
5.1
Electrical supply problems
Replace drive controller
5.1
Thermocouple
Alarm (Optional)
High inlet temperature
Purchase water cooled blower
Reduce inlet temperature
4.2.8
4.2.8
Dirty air filter
Clean or replace filter element
7.1
High ambient temperature
Purchase water cooled blower
4.2.8
Water cooling low flow
Increase flow rate
Decrease water temperature
4.2.8
4.2.8
Blower speed too high
Contact Sonic
Cover
Broken belt (low temp)
Replace belt
4.3, 7.3
Irregular / Excessive
Noise
Blockage in air line
Inspect plumbing and remove blockage
4
Leak in air line
Repair leak
4
Inlet silencer damaged
Replace filter / silencer
7.1
Worn drive belt
Replace belt
4.3, 7.3
Bolts loose on blower / motor assembly
Tighten bolts to proper torque specifications
7.2
Motor mounts loose
Tighten bolts to proper torque specifications
7.2
Blower RPM too high
Contact Sonic
Cover
Blower is receiving vibration from nearby
equipment
Install vibration isolators
Relocate blower assembly
4.2.7
4.2
Belt Jumping Off
¾ inch gap not set
Adjust belt gap to ¾”
4.3, 7.3
Pulleys misaligned
Realign motor pulley
Replace mounting bracket if damaged
7.1
7.1
Blower pulley wobbling
Replace motor
Replace motor bushing
Replace motor pulley
5.1
7.1
7.1
High motor torque
Replace motor with low torque equivalent
5.1
Blower rotating backwards (Incorrect wiring)
Reverse motor wiring
5.1
Belt not set in grooves properly
Install belt correctly
4.3, 7.3
Wrong belt (Not Sonic approved)
Install Sonic supplied belt
4.3, 7.3