EasyManua.ls Logo

Sony Trinitron KV-32TW77 - Safety Related Adjustments; R511 Hold-Down Confirmation and Readjustment; R524 Hold-Down Confirmation and Readjustment

Sony Trinitron KV-32TW77
79 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TH/27
Z27iv
TW78
KV-
32TW77/32TW7
48
SECTION
4
SAFETY
RELATED
ADJUSTMENTS
Ba
R511
CONFIRMATION
METHOD
(HOLD-DOWN
CONFIRMATION)
AND
READJUSTMENTS
The
following
adjustments
should
always
be
per-
formed
when
replacing
the
following
components
(marked
with
[d@
on
the
schematic
diagram).
PM501,
R511,
R632, R645,
R650
®
1.
Preparation
before
confirmation
1)
Remove
R635
on
the
D
board
and
connect
a
variable
resistor
(RV1:
about
4.7k2-10k?2
)
between
pin
@
_
of
IC601
and
B+
line.
2)
Supply
130+42.0V
AC
to
with
variable
auto-
transformer.
2.
Hold-down
operation
confirmation
1)
Turn
the
POWER
switch
ON,
and
receive
entirely
white
signals
and
adjust
ABL
current
to
1760£50yA
with
PICTURE
and
BRIGHT
etc
controls.
2)
Increase
B+
line
voltage
gradually
by
adjusting
the
resistor
of
RV1.
Confirm
that
the
minimum
voltage
is
less
than
142.5V
DC
(27
inch)
140.0V
DC
(32
inch)
whereby
the
raster
disappears
during
operation
of
hold-down
circuit.
NOTE:
When
the
hold-down
circuit
starts
operating,
switch
OFF
the
POWER
of
the
set
immediately.
3)
Turn
the
POWER
switch
ON,
and
receive
dot
signals
and
adjust
ABL
current
to
160+50uA
with
PICTURE
and
BRIGHT
etc
controls.
4)
Increase
B+
line
voltage
gradually
by
adjusting
the
resistor
of
RV1.
Confirm
that
the
minimum
voltage
is
less
than
143.5V
DC
whereby
the
raster
disappears
during
operation
of
hold-down
circuit.
NOTE:
When
the
hold-down
circuit
starts
operating,
switch
OFF
the
POWER
of
the
set
immediately.
3.
Hold-down
readjustment
When
step
2
is
not
satisfied,
readjustment
should
be
performed
by
altering
the
resistance
value
of
R511
(a
component
marked
with
B4).
ba
R524
CONFIRMATION
METHOD
(HOLD-DOWN
CONFIRMATION)
AND
READJUSTMENTS
The
following
adjustments
should
always
be
per-
formed
when
replacing
the
following
components
(marked
with
[@
on
the
schematic
diagram).
1C601,
PM501,
D504,
R509, R524,
R634,
R635,
T501
@
1.
Preparation
before
confirmation
1)
Turn
the
POWER
switch
ON,
and
receive
entirely
white
signals
and
set
the
PICTURE
and
BRIGHT
controls
to
maximum.
2)
Confirm
that
voltage
of
the
check
terminal
of
TP-81
(D
BOARD)
is
more
than
114.0V
DC
(27
inch)
122.3V
DC
(32inch)
when
the
set
is
operating
normally
with
120.0+2.0V
AC
supply.
2.
Hold-down
operation
confirmation
1)
Turn
the
POWER
switch
ON,
and
receive
entirely
white
signals
and
adjust
ABL
current
to
1760+50nA
with
PICTURE
and
BRIGHT
etc
controls
.
2)
Apply
DC
voltage
of
over
130.0V
DC
gradually
to
the
check
terminal
of
TP-85
(D
BOARD)
via
1T40
from
the
DC
stabilized
power
source.
Confirm
that
the
minimum
voltage
is
less
than
137.5V
DC
(27inch)
143.5V
DC
(32inch)
whereby
the
raster
disappears
during
operation
of
hold-down
circuit.
NOTE:
When
the
hold-down
circuit
starts
operating,
switch
OFF
the
POWER
of
the
set
immediately.
3)
Turn
the
POWER
switch
ON,
and
receive
dot
signals
and
adjust
ABL
current
to
160+50ynA
with
PICTURE
and
BRIGHT
etc
controls
.
4)
Apply
DC
voltage
of
over
130.0V
gradually
to
the
check
terminal
of
TP-85
(D
BOARD)
via
1
T40
from
the
DC
stabilized
power
source.
Confirm
that
the
minimum
voltage
is
less
than
138.0V
DC
(27inch)
144.1V
DC
(32inch)
whereby
the
raster
disappears
during
operation
of
hold-down
circuit.
NOTE:
When
the
hold-down
circuit
starts
operating,
switch
OFF
the
POWER
of
the
set
immediately.
3.
Hold-down
readjustment
When
step
2
is
not
satisfied,
readjustment
should
be
performed
by
altering
the
resistance
value
of
R524
(a
component
marked
with
Ba).