2-14
PVM-14L2/20L2
1. Group of models inch 14 (See Table 2-3.)
1. Input a crosshatch signal.
2. Adjust 4-pole magnet, 6-pole magnet of the deflection
yoke and RV708/C board to minimize mis-conver-
gence.
3. When the mis-convergence of the TILT component is
included in the horizontal convergence, make adjust-
ment with the TLH compensator. (Fig. 2-28)
4. Fix the DY spacer with RTV.
5. Fix the 4-pole magnet, 6-pole magnet and TLH of
deflection yoke by applying paint lock.
2. Groups of models inch 20 (See Table 2-3.)
1. Input a crosshatch signal.
2. Adjust 4-pole magnet, 6-pole magnet of the deflection
yoke and RV708/C board to minimize mis-convergence.
3. When the mis-convergence of the TILT component is
included in the horizontal convergence, insert the TLH
compensator into the deflection yoke for adjustment.
(Fig. 2-28)
4. Fix the DY spacer with RTV.
5. Fix the 4-pole magnet, 6-pole magnet and TLH of
deflection yoke by applying paint lock.
6. Fix the XBV knob and APH knob by applying paint
lock.
2-13. G2 Adjustment
Conditions
CONTRAST and BRIGHT : PRESET positions
1. Input a (480/60I) all-black signal to the COMPO-
NENT Y IN connector.
2. Select the cathode that shows the highest pedestal level
among the red, green and blue cathodes.
3. Connect probe of an oscilloscope as indicated below.
Adjust RV709 on the C board so that the pedestal level
becomes standard value as shown in Fig. 2-29.
RED : TP701 or KR
GREEN : TP702 or KG
BLUE : TP703 or KB
GND : TP700
Standard value A = 160 ±2 VDC (14 inch)
Standard value A = 150 ±2 VDC (20 inch)
Fig. 2-29
A
Pedestal level
0 V
DC
2-14. White Balance Adjustment (15k)
1. Connect the 15K window signal to the Y/G terminal of
RGB/COMPONENT IN connector.
2. Enter the service mode.
3. Select COMPONENT.
4. From the front panel, set as follows :
CONTRAST : 80
BRIGHT : 0 (mechanical center)
5. Set the CHROMA knob on the front panel to MIN.
6. Select the following sub menus from the Service Menu
in the order of : [SIGNAL] → [WHITE BALANCE]
and set [COLOR TEMP] to D65.
7. Set [X] of the menu to 313 and [Y] to 329. (Increase
brightness to 100 cd/m
2
or more.)
8. Set [MANUAL/AUTO] to MANUAL.
9. Select [ADJUST GAIN].
10. While fixing G to 700, adjust B and R for optimum
white balance.
11. Upon completion of adjustment, press the [MENU]
key to return to the previous menu.
12. Change the signal level to 3 cd/m
2
.
13. Select [ADJUST BIAS] of the menu.
14. While fixing G to 400 in the same way as in step 10,
adjust B and R for the unity cut-off level.
15. Upon completion of adjustment, press the [MENU]
key to return to the previous menu.
16. Repeat adjustments from step 9 to step 14 until all
specifications are satisfied all at the same time.
(Tracking)
17. Set [COLOR TEMP] to D93.
18. Set [X] of the menu to 283 and [Y] to 298.
19. Set [MANUAL/AUTO] to MANUAL.
20. Repeat adjustments from step 9 to step 16 in the same
way.