6 Instrument Technology
88 Spectra Precision FOCUS 30 User Guide
Suspend Mode
• You can resume working from the same place in the software that you were
before you entered Suspend Mode.
• You can replace a discharged battery with a charged one within a period of
30
seconds.
• In the suspend mode the Radio and the Face2 display will be enabled. Face2
display will show “Waiting (suspend)”
• To turn the instrument On press the Trigger key for one second (one beep) or
connect to the instrument from a remote application.
• To turn the instrument Off press the Trigger key for 3 seconds.
• In Suspend Mode the instrument will turn Off automatically at suspend time
out (default 120
minutes).
Note – During Suspend Mode the Trigger key LED will flash once every five
seconds.
Robotic configuration
A separate control unit is via cable or radio connected with the instrument. For start-
ing the instrument see Instrument, page 87
On Mode
• If the instrument is controlled by a separate controller the instrument will not
go into Suspend Mode.
• For setting the instrument to suspend mode shut down the radio or cable
connection between instrument and separate control unit, and the instrument
will enter suspend mode. The instrument will turn Off automatically at suspend
time out (default 120 minutes).
• The instrument will go to Suspend Mode if the instrument battery is low
(battery capacity less than 5
%), which enables you to replace the instrument
battery within a period of 10 - 15
minutes - detailed information and warnings
at the CU.
• Without replacing the battery the instrument will go to Off Mode if the battery
capacity is less than 2
%.
Note – For Control Unit On/Off and Power save mode please read the appropriate
User Guides.