EasyManua.ls Logo

Spectra Precision Focus 30 - Page 95

Spectra Precision Focus 30
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spectra Precision FOCUS 30 User Guide 79
6 Instrument Technology
of the area being sampled, not to a degradation of the measurement precision, see
Figure 6-2.
Fig. 6-2 Beam divergence
A larger measuring area at longer range is generally better because it enables smaller
objects, such as power lines and antennas, to be detected and accurately measured.
With a smaller measuring area, these small objects can be easily missed. A smaller
measuring area has advantages when measuring tight corners and vertices at close
range. When observing measurements to a tight corner, the distance meter beam

Table of Contents