Prepare for the Replacement Prepare the Library for Power Off
March 2015 HAX Motor Replacement—Spectra T950 Library
5
Turn On Obstruction Scan at Startup
Anobstructionscanslowlyandcarefullymovestherobottocheckthe
libraryforobstructionssuchasTeraPack
®
magazines incorrectlyplacedon
shelves.
Note: Thisutilityisonlyapplicableifyourlibraryisrunning
BlueScale12.0softwareorlater.Ifyouhaveanearlierversionof
theBlueScalesoftware,skiptoMovetheVAXColumntothe
RightEndoftheLibraryonpage 7.
Basedonthetypeofframeintheleft‐mostpositionasyoulookatthe
libraryfromthefront,determinewhetheryouneedtoenableobstruction
scanning.
BulkTAPframe—Enablingobstructionscanatstartupisoptional.If
youchoosenottoenableit,skiptoMovetheVAXColumntotheRight
EndoftheLibraryonpage 7.
Mainframe—Enablingobstructionscanatstartupishighly
recommended.Completethefollowingstepstoenableit.
1. Logintothelibrarywithsuperuseroradministratorprivileges.
2. Fromthetoolbarmenu,selectMaintenance > Tools. TheMaintenance
Toolsscreendisplays.
3. Select Utilities.TheUtilitiesscreendisplays.
4. ClickShow Advanced.TheAdvancedUtilitiesConfirmationscreen
displays.
5. ClickNext.TheUtilitiesscreenrefreshestoshowtheadvancedutilities.