Controller Connections
Instruction Manual
137
Outputs
Description
*ANGLE STATUS
This output will be one of three selections. The selections are the User Defined Value for the associated angle
status of the last fastening cycle. For example: if the last fastening cycle’s angle status was Low, and the User
Defined Value for Low is -, then this output value is-.
The OK User Defined Value is selected when the achieved angle for the defined Step are within specified limits.
The Low User Defined Value is selected when the achieved angle for the defined Step is below the Low Angle
limit.
The High User Defined Value is selected when the achieved angle, for the defined Step, is above the High Angle
limit.
It asserts when the fastening cycle is complete (before the IN CYCLE bit resets). The value resets to zero (0)
when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Step: Audit, Audit-1, Audit-2
OK: User Defined Value
Low: User Defined Value
High: User Defined Value
Spindle: Type the spindle number from which the angle status comes.
*BOLT
This output is the value of the active accumulated bolt count. As the bolt count changes so does this output.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Spindle: Type the spindle number from which the bolt status comes.
*CONSTANT
This value is defined by the end user in the Constant parameter. It asserts when the fastening cycle is complete
(after the IN CYCLE bit resets). The value resets to zero (0) when the tool is commanded to run again.
Size: Can be any size from 0 to 32 bytes depending on Data Type
Configuration:
Data Type: Float, Int8, Int16, Int32, Fixed Point, String
Constant: Type the value of the constant required
CYCLE ABORTED
Asserts when the controller shuts the tool off due to a fault or if the Stop/Abort within Limits parameter is used
and the fastening cycle has a shutoff code of ABORT. Resets when the tool is commanded to run again. Can also
be reset with the RESET RESULTS STATUS input.
Size: 1 bit
Configuration:
Contact Type: Normally Open (N.O.), Normally Closed (N.C.)
Output Type: Normal, Timed, Flash
Minimum ON Time, Time, Period
Spindle: Type the spindle number from which the abort status comes.