Operation
Confirming event messages
✔
An event message with the comment ‘NEW’ is displayed.
u Press ‘ESC’ /r/s. The event message is confirmed.
Displaying event messages
1. Select ‘Event log’ in the main menu.
2. Press ‘SET’ . The event messages are displayed in chronological order (latest message first).
3.
Press rs to page through the event messages.
Incident messages
Incident message Description Type
BCONV
overtemperature
The maximum permissible boost converter temperature has
been exceeded. The inverter feeds no power into the grid until
the maximum permissible temperature is no longer exceeded.
1. Check whether the installation conditions are fulfilled.
2. Contact your installer if this alarm occurs frequently.
Boost converter
malfunction
An internal component of the inverter is defective. It is possible
that the inverter injects into the grid not at all, or with reduced
capacity.
u
Notify your installer.
Boost converter
not connected
The connection of the internal components is interrupted. The
inverter is not injecting into the grid.
u
Notify your installer.
Boost converter
not identified
u
Notify your installer.
Data adoption
failed
A setting failed, for example during initial commissioning,
because it has not been properly adopted.
u
Repeat the setting.
u Contact your installer if this error occurs frequently.
Device is
overheated
In spite of capacity reduction, the maximum permissible
temperature is exceeded. The inverter does not inject into the
grid until the permissible temperature range is reached.
1. Check whether the installation conditions are fulfilled.
2. Contact your installer if this alarm occurs frequently.